NEW QUESTION 22
Which phase of testing includes documenting the test results?

  • A. Phase 3
  • B. Phase 1
  • C. Phase 2

Answer: A

 

NEW QUESTION 23
During the troubleshooting phase, what is the first step?

  • A. Verify
  • B. Isolate
  • C. Test
  • D. Repair

Answer: A

 

NEW QUESTION 24
If you are working on a catwalk, you are required to wear _____?

  • A. Safety belt
  • B. Nothing, your fine on the catwalk
  • C. Full body harness and two lanyards

Answer: C

 

NEW QUESTION 25
Which of the following terms describes the unwanted signal coupling from a disturbing pair of a 4-pair cable channel to a disturbed pair of another 4-pair channel?

  • A. AXT - alien crosstalk
  • B. NEXT - Near end crosstalk
  • C. ACRF - attenuation to crosstalk ratio far end

Answer: A

 

NEW QUESTION 26
Which of the following terms is used to describe mechanical firestop systems?

  • A. Intumescent
  • B. Endothermic
  • C. Elastomeric
  • D. Ablative

Answer: C

 

NEW QUESTION 27
You are pre-terminating cable. Where should the labels be placed?

  • A. Near end
  • B. Far end
  • C. Both ends

Answer: C

 

NEW QUESTION 28
Which type of cabling is installed between a main cross connect and a horizontal cross connect?

  • A. Horizontal
  • B. Second-level backbone
  • C. First-level backbone

Answer: C

 

NEW QUESTION 29
Which pair of a 100-ohm balanced twisted pair patch cable has a white-brown tip and a brown-white ring?

  • A. Pair 3
  • B. Pair 4
  • C. Pair 2
  • D. Pair 1

Answer: B

 

NEW QUESTION 30
What is the required physical topology for a SCS?

  • A. Bus
  • B. Ring
  • C. Tree
  • D. Star

Answer: D

 

NEW QUESTION 31
If the situation requires, a conduit should be terminated _______ the plywood backboard?

  • A. Below
  • B. Through
  • C. Above

Answer: B

 

NEW QUESTION 32
What is the maximum allowable horizontal cable length?

  • A. 50 m (164')
  • B. 10 m (33 ')
  • C. 30 m (100')
  • D. 90 m (295')

Answer: D

 

NEW QUESTION 33
A third 90-degree bend may be permitted in a conduit run if one of the bends is located within ____ of the cable feed end?

  • A. 375 mm (15")
  • B. 450 mm (18")
  • C. 483mm (19")
  • D. 300 mm (12")

Answer: D

 

NEW QUESTION 34
What is the characteristic impedance of Series-6 coaxial cable?

  • A. 100 ohms
  • B. 25 ohms
  • C. 75 ohms
  • D. 50 ohms

Answer: C

 

NEW QUESTION 35
Which is a keyed, contact, moderate loss connector in present use today that is pull & wiggle-proof?

  • A. SMA 906
  • B. Opti-Jack
  • C. Subscriber Connector (SC)
  • D. Straight Tip (ST)

Answer: D

 

NEW QUESTION 36
Which of the following describes a nonmechanical firestop system that forms a hard char when exposed to flame?

  • A. Intumescent
  • B. Endothermic
  • C. Elastomeric
  • D. Ablative

Answer: D

 

NEW QUESTION 37
Which type of optical fiber cable should be color coded with a RED outer cable sheath?

  • A. MM optical fiber with 50 um core diameter (laser-optimized)
  • B. MM optical fiber with 50 um core diameter
  • C. Dispersion-shifted SM optical fiber
  • D. Polarization maintain SM optical fiber

Answer: C

 

NEW QUESTION 38
......