Ultimate Guide to the 300-615 - Latest Jan 21, 2022 Edition Available Now [Q50-Q72]

Share

Ultimate Guide to the 300-615 - Latest Jan 21, 2022 Edition Available Now

2022 Updated Verified Pass 300-615 Exam - Real Questions & Answers


Suitable Audience Profile

Exam 300-615 is proved to be a real game-changer for professionals who want to cement their feet in the world of Cisco Data Center. It allows one to easily gain essential knowledge about the basics of working with data center. Those who have already worked in this field and struggling hard to authenticate inherited competencies can also take-up this test.


Knowing the Associated Certification

Cisco 300-615, or DCIT, is related to two certifications. The first one is CCNP Data Center which is a professional certificate whose key focus is on the key operation, compute, automation, and management skills required to ensure hassle-free data center performance. Accredited individuals are known to be experts in creating viable data center solutions. Note that to earn it, you should pass the core exam 350-601 by code as well.

The second certification associated with Cisco 300-615 is Cisco Certified Specialist - Data Center Operations. As the name says, it is related to the specialist level and imparts the best-of-breed troubleshooting knowledge as well as an understanding of a data center infrastructure.

 

NEW QUESTION 50
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one-by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership.
What is the cause of the issue?

  • A. You forgot to enter the TEP Pool value during the Initial Setup dialogue on APIC1.
  • B. The same Fabric Name value should be used before after wiping all devices.
  • C. The leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.
  • D. Rebooting the APICs and the leaf and spine switches after wiping them is not required.

Answer: C

 

NEW QUESTION 51
Refer to the exhibit.

vPC between switch1 and switch2 is not working. Which two actions are needed to fix the problem? (Choose two.)

  • A. Configure one of the switches as primary for the vPC.
  • B. Activate VLANs on the vPC.
  • C. Configure IP address on the interface.
  • D. Configure vPC peer link and vPC peer keepalive correctly.
  • E. Match vPC domain ID between the two devices.

Answer: B,E

 

NEW QUESTION 52
Drag and drop the commands from the left onto the correct categories on the right.

Answer:

Explanation:

 

NEW QUESTION 53

Refer to an exhibit. An engineer is troubleshooting an upgrade failure on a switch. Which action resolves the issue?

  • A. Reload the same system image.
  • B. Use the same system image as the kickstart image.
  • C. Save the system image in NVRAM.
  • D. Load a new system image.

Answer: D

Explanation:
Section: Management and Operations

 

NEW QUESTION 54
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?

  • A. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server
  • B. 1- Disconnect the power cord
    2- Confirm that all cards are properly seated
    3- Connect the power cord
  • C. 1- Disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server
  • D. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are available
    3- Connect the power cord and power on the server

Answer: A

Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pdf

 

NEW QUESTION 55
Refer to the exhibit.

A network engineer configures an EEM script to get a syslog notification after a configuration change. This message appears when the engineer must make a new configuration to this switch. Which configuration did the engineer neglect to apply in the script for it to function properly?

  • A. event policy-default count 1 time 100
  • B. event syslog occurs 10
  • C. action 2.0 event-default
  • D. event cli match 'configure terminal'

Answer: C

 

NEW QUESTION 56
A customer reports that the Chassis Management Controller fails to receive chassis information from Cisco UCS Manager. Which set of steps resolves the issue?

  • A. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • B. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.
  • C. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.
  • D. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ts/guide/UCSTroubleshooting/UCSTroubleshooti

 

NEW QUESTION 57

Refer to the exhibit. Interface fc1/5 is offline. Which action should be taken to troubleshoot the issue?

  • A. Update the FLOGI database to contain the FLOGI entries for interface fc1/5 in VSAN 100.
  • B. Configure the upstream ports and the server ports to be in VSAN 100.
  • C. Update the FCNs database to contain names for VSAN 100.
  • D. Activate the correct zoneset for VSAN 100.

Answer: B

Explanation:
Section: Compute Platforms

 

NEW QUESTION 58
Refer to the exhibit.

The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?

  • A. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • B. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • C. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • D. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution

Answer: C

Explanation:
Explanation
Need exact snap shot to confirm the following.
The selection of is due to
* SNMP command has the key word "oid".
* The command "switchto vdc Core" show run in "enable" mode, not "config t" mode.

 

NEW QUESTION 59
A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action does an engineer take to prevent this issue from reoccurring?

  • A. Change the SFP to operate at 4 Gbps instead of 2 Gbps.
  • B. Run the switchport ignore bit-errors command on the interface.
  • C. Verify that the SFPs are supported.
  • D. Run the shutdown and then no shutdown command on the interface.

Answer: B

 

NEW QUESTION 60

Refer to the exhibit. Partial configuration from N9K-1 and N9K-2 is included. The client has two WANs connected.
* WAN-1 is for normal business-day activities.
* WAN-2 is for server backups during nonworking hours of 1:00 a.m. to 5:00 a.m. daily.
The client says that at the scheduled time for backup, the data center server failed to use the WAN-2 link to back up the servers to the cloud backup system. What is the solution to this problem?

  • A. The Cisco Nexus switch must be configured with one applet because a configuration with two applets will fail.
  • B. The event timer must be written in epoch time format.
  • C. The applet called "Backup" must include an action to remove the current static route.
  • D. The Cron entry must be configured without double quotes.

Answer: C

Explanation:
Section: Automation
Explanation

 

NEW QUESTION 61

Refer to the exhibit. An engineer is troubleshooting why user1, user2, and user3 from group STORAGE- ADMINISTRATOR in Microsoft Active Directory cannot log in to the Cisco MDS SSH CLI. Which action resolves the issue?

  • A. Include specific users into MDS role configuration.
  • B. Configure SSH logins on Cisco MDS switch.
  • C. Integrate Cisco MDS with Microsoft Active Directory.
  • D. Configure the role name to match the group name on Microsoft Active Directory.

Answer: D

Explanation:
Section: Storage Network
Explanation

 

NEW QUESTION 62
Refer to the exhibit.

After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?

  • A. Reboot the switch
  • B. Reboot the guestshell
  • C. Resync the database
  • D. Recreate the guestshell

Answer: B

 

NEW QUESTION 63
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?

  • A. Install Server Firmware, then Install Infrastructure Firmware
  • B. Install infrastructure Firmware, then Install Hypervisor Firmware.
  • C. Install Hypervisor Firmware, then Install Infrastructure Firmware
  • D. Install Infrastructure Firmware, then Install Server Firmware.

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Ma

 

NEW QUESTION 64
Refer to the exhibit.

After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?

  • A. Reboot the switch
  • B. Reboot the guestshell
  • C. Resync the database
  • D. Recreate the guestshell

Answer: B

 

NEW QUESTION 65
An engineer is troubleshooting a fabric discovery failure. Which two requirements must an engineer verify about switch connectivity to solve the problem? (Choose two.)

  • A. Leaf nodes must connect to spine nodes only.
  • B. A Cisco APIC must be attached to leaf nodes.
  • C. Spine nodes must connect to other spine nodes.
  • D. A Cisco APIC must be attached to a spine node only.
  • E. A Cisco APIC must be dual-attached to two separate spine nodes.

Answer: A,B

 

NEW QUESTION 66
Refer to the exhibit.

Sw1 and Sw2 are two Cisco Nexus 9000 Series Switches that run Cisco NX-OS. They are VTEPs in the same vPC domain. Which statement describes what happens in this scenario?

  • A. Sw1 performs the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs.
  • B. Sw1 and switch 2 perform the VxLAN multicast encapsulation and decapsulation for all traffic associated with the VxLAN VNIs, depending on the hashing.
  • C. Sw1 drops all traffic because there is no (S, G) OIF list to encapsulate VXLAN multicast packets and send them out to the underlay network through the uplink interfaces.
  • D. Sw2 did not send an IP PIM register to the rendezvous point for the multicast group of the VXLAN VNI.

Answer: A

 

NEW QUESTION 67
Refer to the exhibit. VSAN traffic is not routed as expected. Which action should be taken to resolve the issue?

  • A. Reset the inactivity timer on switch-2
  • B. Configure the hello timer to match the neighbor
  • C. Configure the FSPF dead interval with a value higher than 80 seconds
  • D. Reset the error packet counter

Answer: B

Explanation:
Reference:
https://www.cisco.com/en/US/docs/switches/datacenter/nexus5500/sw/troubleshooting/guide/n5500_ts_sans.html

 

NEW QUESTION 68
An engineer troubleshoots a VXLAN EVPN data center. The applications in the data center fail to reach the DNS server that is located at IP 10.10.10.10. The engineer examines the BGP EVPN routing table and notes that the IP prefix route covers the DNS server is missing. Which action resolve the issue?

  • A. Set the IP prefix route to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[0]:[0.0.0.0]/216 in the routing table
  • B. Configure an IP ARP entry to represent [4]:[0300.0000.00fc.bd00.0309l[32]:[10.10.10.10]/136,n the routing table
  • C. Set the IP prefix route to represent [5]:[0]:[0]:[32]:[10.10.10.10]/224 in the routing table.
  • D. Configure an IP ARP entry to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[32]:[10.10.10.10]/272 in the routing table

Answer: C

 

NEW QUESTION 69
Refer to the exhibit.

Interface fc1/5 is offline. Which action should be taken to troubleshoot the issue?

  • A. Update the FLOGI database to contain the FLOGI entries for interface fc1/5 in VSAN 100.
  • B. Configure the upstream ports and the server ports to be in VSAN 100.
  • C. Update the FCNs database to contain names for VSAN 100.
  • D. Activate the correct zoneset for VSAN 100.

Answer: B

 

NEW QUESTION 70
Refer to the exhibit.

An engineer must connect N2K-Fex-1 and N5K-Core-1 so that the traffic flow between the two devices uses load balancing. After inspecting the statistics of the interconnecting interfaces, the engineer concludes that only one link is used. Which action resolves the problem?

  • A. Configure the pinning max-link as 2.
  • B. Configure each uplink to be a member of a separate LACP port channel.
  • C. Configure source-destination load balancing on N5K-Core-1.
  • D. Configure destination-mac load balancing on N5K-Core-1

Answer: A

Explanation:
Explanation
https://www.cisco.com/c/m/en_us/techdoc/dc/reference/cli/n5k/commands/pinning-max-links.html

 

NEW QUESTION 71
A system administrator adds two vNICs to an existing service profile that is used to run a vSphere environment to support disjoint Layer 2 network connectivity. However, after the server is rebooted, the host is not accessible on the network Which action resolves the issue?

  • A. Remove all existing vNICs and add them in the desired order.
  • B. Create a vNIC placement policy to avoid adapter renumbering
  • C. Add the disjoint Layer 2 VLANs to an existing vNIC rather than adding new vNICs
  • D. Build a new service profile with the desired network configuration

Answer: C

 

NEW QUESTION 72
......


What is the duration, language, and format of Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure Exam

  • Language - English
  • Passing Score 80%
  • Number of Questions: 60 - 70
  • Length of Examination: 90 minutes
  • Format: Multiple choices, multiple answers

 

Dumps Moneyack Guarantee - 300-615 Dumps Approved Dumps: https://www.actual4exams.com/300-615-valid-dump.html

Verified 300-615 Exam Dumps PDF [2022] Access using Actual4Exams: https://drive.google.com/open?id=1RJgtSQA070CsKM50mqa5wFLM86BQ353K